Wiki Page: ASLM: Semaphore failure when launching application on Runtime Environment - Server for COBOL 5.1

$
0
0
Problem: After installing and licensing Server for Cobol 5.1 correctly you receive a ASLM: Semaphore failure when trying to execute an application. Resolution: To run a Micro Focus application on a machine where the runtime has been installed, the environment variable %ASLMNET% must be set. In the value of this variable, the name of your server can be used or the IP address of the server. On the server, to run a Cobol application, the environment variable %ASLMNET% is not required. If you need to have the same application (with the environment variable %ASLMNET%) on all computers, then the IP address must be used in the value of the environment variable %ASLMNET%.